GENERAL STACK LUG RELOCATION SPECIFICATION:
This specification applies to the following types of trench shields:
3M, 4L, 4M, 6M, 8M, T, E, N, K, and LD
SPECIFICATIONS:
- All welding shall be performed according to the Structural Welding Code for Steel – AWS D1.1-90
- A certified welder shall perform all welding.
- 3/16″ steel sheet with a 55,000 psi minimum yield strength shall be used to replace the skin plate cut away from the collars.
- The Stack tube shall be manufactured by GME.
PROCEDURE
- Cut off GME stack tube location on the inside skin of the shield.
- Repair any holes on the skin that may have occurred during the cutting process. Once hole(s) are welded closed, clean the area thoroughly with a wire brush or grinding wheel.
- Clean the area to be welded thoroughly with a wire brush or grinding wheel.
- Weld the replacement stack tube to the end of the shield, using a all around 3/16″ fillet weld.
NOTE