Build-A-Box (ECP) Panel Puncture Repair
General Panel Puncture Repair Specification:
This specification applies to the following types of trench shields:
Build-A-Box (ECP)
Specifications
- All material must be 6061-T6 Aluminum plate
- Patch plate size to be tear size plus 3" on all sides
- Patch plate to be less than 18" x 18"
Procedure
- Plate patch plate over tear.
- Weld 3/16" full weld, full thickness/continuous
Note
In accordance with OSHA regulations, a Registered Professional Engineer must observe and provide written conformation that the above specification has been followed as authorized by the factory or the Tabulated Data will no longer be valid.